RAVONA IGT-300 Glove Integrity Tester:
The RAVONA IGT-300 is a standalone cabinet designed to test the integrity of gloves used in aseptic and containment environments, specifically within Isolators and R.A.B.S systems. Equipped with a Human-Machine Interface (HMI) and a SCADA system, the IGT-300 provides an advanced, user-friendly solution for verifying glove integrity to ensure the safety of both operators and products in Aseptic and Containment enviorments.

What is the RAVONA IGT-300 Glove Integrity Tester?
-
The IGT-300 is an independent testing cabinet.
that allows users to test the integrity of multiple gloves simultaneously, used within Isolators or R.A.B.S systems. It is a versatile, automated solution that checks for leaks or defects in gloves that could compromise containment or aseptic conditions. The IGT-300 Glove tester provides a secure, non-invasive method to ensure gloves remain intact and fully functional.
The IGT-300 can test the gloves in a dedicated trolley or test the glove on the glove ports of the system, with wireless communication. The option of wireless testing on the glove ports combines the solution of the IGT-300 and IGT-400 systems.
We Comply with the Following Standards and Guidelines

Benefit from optimal glove integrity, and maximum peace of mind.
RAVONA IGT-300 Glove Integrity Tester
Key Features of the RAVONA IGT-300 Glove Integrity Tester
Standalone Cabinet Design:
- The IGT-300 operates as a standalone testing unit, offering a compact, efficient solution for glove integrity checks. It features an integrated HMI and SCADA system, allowing operators to easily manage and monitor tests.
- Multiple glove testing: Capable of testing multiple gloves in parallel, it can be integrated with isolators or R.A.B.S systems with big amount of gloves.
Advanced Leak Detection:
- The IGT-300 uses automated cycle technology to test gloves for leaks or integrity failures, detecting halls as small as 50-100 microns. It provides precise and reliable leak detection to ensure that gloves are fully intact and safe for use in Aseptic or Containment environments.
Integration with SCADA Systems:
- The IGT-300 is seamlessly integrated with SCADA systems for centralized monitoring and control. This integration enables the automatic transmission of test results, alarms, and system statuses, providing comprehensive oversight and facilitating automated workflows for better efficiency and compliance.
- Operators can monitor glove integrity status in real-time through the SCADA interface, ensuring that any integrity issues are promptly identified and addressed.
Real-Time Testing with HMI:
- The HMI interface provides intuitive controls for operators to perform testing, review results, and manage testing schedules. The real-time feedback ensures that glove integrity is continuously checked, preventing any compromise in operator safety or product sterility.
CFR 21 Part 11 Compliance:
- The IGT-300 complies with CFR 21 Part 11 standards, ensuring that all data generated during testing is properly recorded and stored with full audit trail capabilities. This makes it suitable for use in regulated environments where compliance with data integrity standards is essential.
RFID Integration for Traceability:
- Equipped with RFID tags, the IGT-300 provides complete traceability of the gloves being tested. Each glove can be uniquely identified, and testing history can be tracked to ensure full accountability and compliance with internal procedures.
Advanced Reporting and Data Management:
- The system generates comprehensive PDF reports for each test, detailing the glove tested, the test results, and any potential leaks detected. These reports are automatically generated and can be easily retrieved and archived for compliance purposes.
- Reports are stored in a secure digital format, allowing for easy access and sharing for auditing or regulatory review.
User-Friendly Interface:
- The HMI interface simplifies the glove testing process, allowing operators to easily select glove types, initiate tests, and interpret results. With its clear visual indicators and easy-to-navigate controls, operators can ensure accurate testing with minimal training.
Automatic Failures Detection and Alerts:
- If a glove fails the integrity test, the IGT-300 will automatically alert the operator with a visual or audible signal. This feature helps to quickly identify issues and prevent further exposure to hazardous or sensitive materials.
Flexible Testing for Aseptic and Containment Environments:
- Whether used for aseptic filling applications, containment isolators, or R.A.B.S systems, the IGT-300 is adaptable for a wide range of applications. It provides essential glove integrity testing in environments where maintaining safety and sterility is paramount.
- It can test the gloves on the trolley or wirelessly on the glove ports.
Why Choose RAVONA for Glove Integrity Testing?
The IGT-300 ensures that gloves used in critical environments remain intact, protecting both personnel and product integrity.
Works seamlessly within SCADA systems, offering centralized monitoring and real-time feedback on glove integrity status.
Fully CFR 21 Part 11 compliant, ensuring your glove testing processes meet the highest regulatory standards.
Detects leaks as small as 50-100 microns, providing accurate results and preventing exposure to hazardous substances.
Automatically generates PDF reports, providing secure storage of results for easy access and compliance auditing.
Simple and intuitive controls with an HMI interface ensure seamless glove testing operations for your team.
Applications of the RAVONA IGT-300 Glove Integrity Tester
The RAVONA IGT-300 is ideal for use in environments where gloves are critical to both operator safety and environmental containment. Typical applications include:
Aseptic Filling Lines: Ensures glove integrity during aseptic processing, preventing contamination of sterile products.
Containment Isolators: Validates glove integrity in environments dealing with hazardous materials or potent substances to protect operators and the environment.
R.A.B.S Systems: Used in R.A.B.S systems to ensure gloves are leak-proof and maintain the integrity of aseptic conditions during processing.
Pharmaceutical and Biotech Manufacturing: Ensures that gloves used in the production of pharmaceuticals, biologics, and vaccines are safe and do not compromise product quality.
Cell and Gene Therapy: Validates glove integrity in the handling of biological agents and other sensitive materials in therapeutic applications.
Why Choose RAVONA for Glove Testing?
- Industry Expertise: RAVONA has extensive experience in the design and manufacturing of advanced containment and aseptic Isolators and R.A.B.S systems, ensuring that all of our testing solutions, like the IGT-200, 300, and 400, meet the highest standards for performance and safety.
- Comprehensive Solutions: The IGT-300 is part of a complete portfolio of testing solutions, enabling full compliance and efficient quality assurance for aseptic and containment systems.
- Commitment to Safety and Compliance: At RAVONA, we are committed to providing advanced tools that enhance